電加熱恒溫箱有什么機(jī)械故障呢

時(shí)間:2021-07-16 08:52:31 來源:[db:來源] 點(diǎn)擊:334次

電加熱恒溫箱有什么機(jī)械故障呢?出現(xiàn)了常見故障又應(yīng)當(dāng)如何開展檢修呢?對(duì)于這2個(gè)難題人們接下去逐一認(rèn)識(shí)一下。

What is the mechanical failure of the electric heating thermostat? How to carry out the overhaul when there are common faults? For these two problems, people will go on to understand one by one.

1、電加熱恒溫箱工作中室溫不勻稱,出現(xiàn)這種情況,應(yīng)查驗(yàn)恒溫箱箱里物件是不是阻塞送風(fēng)模式道通風(fēng)口或是是進(jìn)氣口,還是恒溫箱箱里物件過多。

1. The room temperature of the electric heating thermostat is not symmetrical. In this case, it should be checked whether the objects in the thermostat block the ventilation outlet of the air supply mode or the air inlet, or whether there are too many objects in the thermostat.

2、培養(yǎng)箱不加熱同時(shí)伴有報(bào)警聲,但培養(yǎng)箱循環(huán)風(fēng)機(jī)正常工作,同時(shí)溫控示“———",此故障為培養(yǎng)箱傳感器損壞,更換一下傳感器就可以了。

2. The incubator is not heated and accompanied by alarm sound, but the incubator circulating fan works normally, and the temperature control "-". This fault is the incubator sensor damage, just replace the sensor.

3、電熱培養(yǎng)箱打開電源開關(guān)出現(xiàn)跳閘現(xiàn)象,出現(xiàn)此類情況可直接考慮更換培養(yǎng)箱加熱管,另保險(xiǎn)絲座損壞也會(huì)出現(xiàn)此現(xiàn)象,但極少見。

3. The switch of power supply in the electrothermal incubator trips, which can be directly considered to replace the incubator heating tube. In addition, the fuse holder damage will also occur, but it is rare.

4、恒溫箱接入開關(guān)電源后,開啟恒溫箱電源總開關(guān)無顯示信息,多見保險(xiǎn)管融斷,拆換就能,若保險(xiǎn)管完好無損,立即拆換電源總開關(guān)。

4. When the thermostat is connected to the switching power supply, the main switch of the power supply of the thermostat has no display information. Most of the fuses are broken, and the fuses can be removed. If the fuses are intact, the main switch of the power supply should be removed immediately.

5、電熱培養(yǎng)箱不加熱但溫控儀顯示正常,培養(yǎng)箱此故障多為加熱損壞,更換即可,在檢修培養(yǎng)箱該故障時(shí)應(yīng)確保循環(huán)風(fēng)機(jī)正常運(yùn)行。如果培養(yǎng)箱循環(huán)風(fēng)機(jī)不運(yùn)轉(zhuǎn)也會(huì)引起不加熱現(xiàn)象,但培養(yǎng)箱箱內(nèi)溫度會(huì)有5℃左右的溫升,打開箱門時(shí)會(huì)有少量焦糊味道,比較容易判斷是培養(yǎng)箱加熱管或者是循環(huán)風(fēng)機(jī)故障。

5. The incubator is not heated, but the temperature controller shows normal. The incubator is usually damaged by heating. It can be replaced. When overhauling the incubator, the circulating fan should be ensured to run normally. If the circulating fan of the incubator does not work, it will also cause no heating phenomenon, but the temperature in the incubator will rise about 5 C. When the door of the incubator is opened, there will be a small amount of burnt taste. It is easier to judge whether the incubator heating pipe or the circulating fan is out of order.http://www.crxyq.cn/


 